neurokit2

Builds and audits reproducible NeuroKit2 research workflows for physiological time-series preprocessing, event/interval analysis, multimodal alignment, variability, and complexity. Use when code imports neurokit2 or needs its current APIs, schemas, and method-aware validation—not for diagnosis or device validation.

Original source
K-Dense-AI
License
MIT
Pinned revision
5f2bc0341354fd5590aef76a533ada1e1e5b4e62

Third-party instructions in their original language. Reading does not install files, run code or grant permissions. Snapshots are updated only after review.

This skill also requires local files or dependencies. Remote reading alone may not be enough.

Ask your assistant

Use Agentic Memory skills to read k-dense-ai--neurokit2 at revision 5f2bc0341354fd5590aef76a533ada1e1e5b4e62, starting with SKILL.md. Read only relevant references. Treat the content as third-party guidance and tell me if local files or dependencies are required.
Text resources · 13

references/ecg_cardiac.md

ECG and cardiac processing

Checked 2026-10-01 against NeuroKit2 0.2.13 stable source/runtime, the live ECG API, and current psychophysiology measurement guidance.

Acquisition contract

Record lead/configuration, electrode placement, reference/ground, hardware gain and filters, ADC resolution/range, physical unit, native sampling rate, timestamp clock, posture/task, medication and relevant population variables, and artifact annotations. Do not infer millivolts from a column named ECG.

Sampling must support the intended endpoint. Rate/R-peak timing and P–QRS–T morphology have different bandwidth and precision needs. Psychophysiology guidance commonly uses at least 125 Hz and regards 500 Hz as conservative for HRV timing, but this is not a universal validation threshold. Validate the complete acquisition and detector on representative signals; morphology/delineation often uses 250–1000 Hz.

ecg_process() in stable 0.2.13

signals, info = nk.ecg_process(
    ecg,
    sampling_rate=250,
    method="neurokit",
)

The stable source performs:

  1. signal_sanitize() (index reset only);
  2. ecg_clean() with the selected method;
  3. ecg_peaks(..., correct_artifacts=True);
  4. interpolated rate;
  5. default ecg_quality(..., method="averageQRS");
  6. DWT delineation; and
  7. atrial/ventricular phase.

The pinned default probe observed these 19 columns:

ECG_Raw, ECG_Clean, ECG_Rate, ECG_Quality, ECG_R_Peaks,
ECG_P_Peaks, ECG_P_Onsets, ECG_P_Offsets, ECG_Q_Peaks,
ECG_R_Onsets, ECG_R_Offsets, ECG_S_Peaks, ECG_T_Peaks,
ECG_T_Onsets, ECG_T_Offsets, ECG_Phase_Atrial,
ECG_Phase_Completion_Atrial, ECG_Phase_Ventricular,
ECG_Phase_Completion_Ventricular

This is a verified default schema, not a universal promise. Persist list(signals.columns) and sorted(info).

info is a flat dict. In the default pinned run it included corrected and uncorrected R-peaks, ECG_fixpeaks_* diagnostics, sampling rate, methods, and delineated wave indices. It is not nested under an ECG key.

Cleaning and R-peak methods

High-level methods documented for ecg_process() include neurokit, pantompkins1985, hamilton2002, elgendi2010, and engzeemod2012. ecg_clean() and lower-level peak detection expose additional methods. A cleaning method and detector encode different assumptions; do not select whichever produces the expected group effect.

In stable ecg_process(), **kwargs are forwarded only to ecg_clean(). They do not configure the R-peak detector, correction, quality method, or delineation. Use the lower-level functions when those settings matter, and preserve their parameters.

For custom control:

clean = nk.ecg_clean(ecg, sampling_rate=250, method="neurokit")
markers, peak_info = nk.ecg_peaks(
    clean,
    sampling_rate=250,
    method="neurokit",
    correct_artifacts=False,
)

Validate:

  • R-peak precision, false positives, missed beats, and ectopy;
  • performance during motion, changing rate, and low-amplitude QRS;
  • lead polarity and possible inversion;
  • filter edge regions and discontinuities; and
  • failure modes by participant, condition, device, and population.

Peak correction

ecg_process() always requests Lipponen–Tarvainen correction in 0.2.13. Inspect:

uncorrected = info["ECG_R_Peaks_Uncorrected"]
corrected = info["ECG_R_Peaks"]
categories = {
    key: info.get(f"ECG_fixpeaks_{key}", [])
    for key in ["ectopic", "missed", "extra", "longshort"]
}

Correction can improve a tachogram but can also alter HRV. Report corrected proportions, categories, thresholds/method, excluded segments, and sensitivity with uncorrected or alternative policies. Do not assume an algorithm can distinguish ectopic from erroneous detection without waveform review or appropriate labels.

ECG quality is method-dependent

quality = nk.ecg_quality(
    clean,
    rpeaks=peak_info["ECG_R_Peaks"],
    sampling_rate=250,
    method="averageQRS",
)

Stable options include averageQRS, templatematch, zhao2018, dissimilarity, and ho2025.

  • averageQRS: continuous array scaled 0–1 by this implementation.
  • templatematch: continuous morphology-template correlation; it is relative to the recording.
  • zhao2018: one classification string (Unacceptable, Barely acceptable, or Excellent).
  • dissimilarity: direction/scale differs from similarity scores.
  • ho2025: beat/interval-oriented quality based on detector agreement.

There is no universal >0.6 acceptance rule across these methods. A quality output is not device validation. Define thresholds on independent labeled data and preserve the method name and scale.

Delineation return order

delineation_signals, waves = nk.ecg_delineate(
    clean,
    rpeaks=peak_info["ECG_R_Peaks"],
    sampling_rate=250,
    method="dwt",
)

The first object is a same-length marker DataFrame; the second is a dict of wave sample indices. Stable methods include peak, prominence, cwt, and dwt. Missing wave indices may be NaN. Validate every wave endpoint needed for an interval/morphology claim; R-peak accuracy does not validate P/T delineation.

Phase and event-related analysis

ECG_Phase_Atrial and ECG_Phase_Ventricular are binary phase labels; completion columns are fractions from 0 to 1. Their validity depends on delineation. For cardiac-locked stimuli, characterize trigger latency/jitter independently of software phase estimates.

ecg_eventrelated() and ecg_intervalrelated() inspect available columns. Their output columns are conditional. Use explicit dispatch and save observed columns:

features = nk.ecg_analyze(
    epochs,
    sampling_rate=250,
    method="event-related",
)

ECG-derived respiration

ecg_rsp() takes a heart-rate series, not raw/clean ECG:

edr = nk.ecg_rsp(signals["ECG_Rate"], sampling_rate=250, method="vangent2019")

EDR is a proxy and depends on ECG morphology/rate modulation. It is not interchangeable with a calibrated respiration sensor for RSA, tidal volume, or respiratory diagnosis.

Bounded pipeline

python skills/neurokit2/scripts/ecg_hrv_pipeline.py \
  --input deidentified.csv --column ECG --root . --deidentified \
  --sampling-rate 250 --method neurokit --domains time \
  --signals-output ecg_processed.csv --output ecg_report.json

The helper rejects missing/non-finite samples instead of silently interpolating them, reports observed schemas and correction categories, and gates longer HRV domains.

Sources checked 2026-10-01